# Correction values for AMP / power
AMP_POWER
# power in dB, correction in %
	 -4.900000	 0.00000000
	 -4.56209534	 -12.40977032
	 -4.15156342	 -21.64229346
	 -3.67752052	 -28.26154493
	 -3.12785070	 -32.43081457
	 -2.47677798	 -34.14078843
	 -1.71674100	 -33.74834385
	 -0.86671932	 -31.96974206
	 0.03884371	 -29.56959414
	 0.97927611	 -26.96451004
	 1.95283474	 -24.27489924
	 2.95035018	 -21.65539039
	 3.96424699	 -19.19894071
	 4.98216175	 -16.99473190
	 5.99914840	 -15.04845004
	 6.80524206	 -13.69229027
	 6.89248330	 -13.60193804
	 6.99089376	 -13.45442018
	 7.88750730	 -12.14583761
	 8.86952966	 -10.89946107
	 9.83867399	 -9.82839426
	 10.80122879	 -8.88361213
	 11.75021945	 -8.06890114
	 12.69526369	 -7.33765450
	 13.64004615	 -6.67148093
	 14.58722305	 -6.05902872
	 15.53449464	 -5.50131679
	 16.49200940	 -4.97612755
	 17.45542248	 -4.49131953
	 18.42656571	 -4.04264703
	 19.40049886	 -3.63511982
	 20.37900916	 -3.26345924
	 21.36047329	 -2.92678796
	 22.24594212	 -2.65161457
	 22.32467072	 -2.63997795
	 22.42305182	 -2.61116835
	 23.30798857	 -2.36599338
	 24.29974721	 -2.11447467
	 25.28958916	 -1.89088468
	 26.28230334	 -1.68932061
	 27.27625635	 -1.50861993
	 28.27123341	 -1.34678971
	 29.26767850	 -1.20173539
	 30.25871217	 -1.07421474
	 31.25766603	 -0.95772441
	 32.25610723	 -0.85401043
	 33.24670320	 -0.76349226
	 34.24369857	 -0.68113419
	 35.24256872	 -0.60728641
	 36.24134845	 -0.54146113
	 37.23391512	 -0.48375396
	 38.13443978	 -0.43606373
	 38.22399646	 -0.43254637
	 38.31656109	 -0.42863372
	 39.21480838	 -0.38666464
	 40.20775104	 -0.34540821
	 41.20610480	 -0.30801033
	 42.19964362	 -0.27509173
	 43.19272200	 -0.24572731
	 44.19248732	 -0.21902137
	 45.18669964	 -0.19556962
	 46.18557009	 -0.17436540
	 47.18833117	 -0.15526436
	 48.18800959	 -0.13839393
	 49.19282460	 -0.12315129
	 50.19546346	 -0.10966476
	 51.19492345	 -0.09775595
	 52.20024279	 -0.08697471
	 53.21258844	 -0.07720557
	 54.11197213	 -0.06962029
	 54.22142746	 -0.06861150
	 54.31783823	 -0.06790558
	 55.22492973	 -0.06108018
	 56.22929610	 -0.05436015
	 57.22746344	 -0.04847757
	 58.22772594	 -0.04320197
	 59.23573176	 -0.03840310
	 60.22788196	 -0.03431479
	 61.24037322	 -0.03045833
	 62.22936987	 -0.02724396
	 63.23829536	 -0.02421039
	 64.24047881	 -0.02156210
	 65.23124053	 -0.01927545
# Correction values for AMP / phase
AMP_PHASE
# power in dB, correction in degrees
	 -4.900000	 0.00000000
	 -4.56209534	 0.36395552
	 -4.15156342	 0.91435815
	 -3.67752052	 1.56305812
	 -3.12785070	 2.29782604
	 -2.47677798	 3.11715420
	 -1.71674100	 3.96336290
	 -0.86671932	 4.70845485
	 0.03884371	 5.28078440
	 0.97927611	 5.70746078
	 1.95283474	 6.01721012
	 2.95035018	 6.20986889
	 3.96424699	 6.29126348
	 4.98216175	 6.25430953
	 5.99914840	 6.14180759
	 6.80524206	 5.99474828
	 6.89248330	 6.05858955
	 6.99089376	 6.03736017
	 7.88750730	 5.80972616
	 8.86952966	 5.50719505
	 9.83867399	 5.16827825
	 10.80122879	 4.80746719
	 11.75021945	 4.44982595
	 12.69526369	 4.10967878
	 13.64004615	 3.79069847
	 14.58722305	 3.51837972
	 15.53449464	 3.27343434
	 16.49200940	 3.05402535
	 17.45542248	 2.87817591
	 18.42656571	 2.73155813
	 19.40049886	 2.60843448
	 20.37900916	 2.51250387
	 21.36047329	 2.43892568
	 22.24594212	 2.37971122
	 22.32467072	 2.32323374
	 22.42305182	 2.31620737
	 23.30798857	 2.27319204
	 24.29974721	 2.23341766
	 25.28958916	 2.20734304
	 26.28230334	 2.18783096
	 27.27625635	 2.17306916
	 28.27123341	 2.16628122
	 29.26767850	 2.16708017
	 30.25871217	 2.16831592
	 31.25766603	 2.17368226
	 32.25610723	 2.17327202
	 33.24670320	 2.18418762
	 34.24369857	 2.19950966
	 35.24256872	 2.20066648
	 36.24134845	 2.22185608
	 37.23391512	 2.25197853
	 38.13443978	 2.25752387
	 38.22399646	 2.32888501
	 38.31656109	 2.33566899
	 39.21480838	 2.34843336
	 40.20775104	 2.38274219
	 41.20610480	 2.42491050
	 42.19964362	 2.44801494
	 43.19272200	 2.47274919
	 44.19248732	 2.50560117
	 45.18669964	 2.52957897
	 46.18557009	 2.52319570
	 47.18833117	 2.51038358
	 48.18800959	 2.47597138
	 49.19282460	 2.43402727
	 50.19546346	 2.38132140
	 51.19492345	 2.33802142
	 52.20024279	 2.29079407
	 53.21258844	 2.23409095
	 54.11197213	 2.20138834
	 54.22142746	 2.13328232
	 54.31783823	 2.12238312
	 55.22492973	 2.12188061
	 56.22929610	 2.07262788
	 57.22746344	 2.04348122
	 58.22772594	 2.03565750
	 59.23573176	 2.03887590
	 60.22788196	 2.04951168
	 61.24037322	 1.98626247
	 62.22936987	 2.02554950
	 63.23829536	 2.01638789
	 64.24047881	 2.01217620
	 65.23124053	 1.99893105
	 120.0000000	 1.99893105
# real probe input power [W] (at -4.900000dB)
AMP_VALUE
	547.945251
# corresponding preamplifier module names
PREAMP_NAME
	XBB19F$2HP
# offset to minimum possible attenuation in [dB]
SCALE_OFFSET_DB
	1.1
# absolute phase value at highest allowed power level [degree]
ABSOLUTE_PHASE_DEGREE
	41.95
AMPLIFIER_ID
	W144061/001207
PREAMP_MODULE_ID
	Z102026/00653
# NAME_OF_TABLE: trx2_77Se_amp2_preamp3
# DATE_OF_ORIGIN: 2022/01/11-15:28:48.979
##END
# hash MD5: 31 CC 47 97 55 07 0F 87 01 48 41 2D A3 BD 6F A3